Upgrade or retrofit your FAAC 620 (or compatible) barrier gate with the FAAC 428163.5 Hinged Breakaway Bracket Kit with Sensor — a stainless-steel breakaway support bracket designed to protect your barrier beam from damage due to accidental impacts or obstructions. This bracket allows the round beam to pivot (break away) under force, and the built-in sensor (micro-switch) sends a signal to the barrier control system to stop or halt operation whenever the beam has been displaced. For safety, longevity, and reduced maintenance, this kit includes all necessary brackets, hardware, and the sensor. It requires the addition of the “S Spring” FAAC 63000169 for proper tension and pivot action on pivoting round arms. Ideal for commercial, residential, or public barrier installations where durability and safety are priorities.
Ensure Compatibility: Confirm your barrier uses a round beam arm and supports the pivoting (hinged) configuration. Make sure to have the FAAC 620 or B680H barrier model.
Obtain the Required Spring: Acquire the “S Spring” (FAAC 63000169) which is necessary for proper balancing and return of the arm when the breakaway bracket operates.
Bracket Installation: Remove or adjust any existing fixed beam bracket. Mount the hinged breakaway bracket in its place using the provided stainless steel hardware, ensuring alignment with the beam pivot axis.
Sensor (Micro-switch) Mounting: Mount the micro-switch sensor as per the manual. Typically you’ll need to drill a 10 mm hole in a designated location (often in the bracket or housing), attach the switch with supplied screws & washers, then wire its contacts in series with the barrier’s stop or safety circuit.
Adjust Tension / Spring: Install the S Spring and adjust tension so that the beam returns properly after the breakaway event and the bracket pivots smoothly without undue force.
Test Functionality: Manually trigger the breakaway action (simulate an impact) to verify the bracket pivots and the sensor activates, stopping the barrier or registering the event. Check that normal beam operation resumes after resetting.
The sensor ensures that the system detects when the beam moves beyond normal limits (breakaway), which helps prevent damage to both the beam and barrier motor.
Stainless steel construction provides improved corrosion resistance and long-term durability.
Using the bracket properly helps avoid costly replacements of beams or hinge points.
Warranty / guarantee depends on FAAC’s distributor / region; ensure that the installation follows manufacturer guidelines so that warranty remains valid.
Regular inspections recommended, especially after impacts or adverse weather, to ensure the bracket and sensor remain aligned and functional.
Use only the specified S Spring (63000169) to avoid inappropriate tension or stress on the bracket.
Lubricate hinge pivot points periodically to maintain smooth operation.
Protect the wiring of the sensor (micro-switch) from water ingress or mechanical damage.
In high-traffic or heavy-usage installations, inspect the breakaway bracket frequently for signs of fatigue or wear.
Consider having spare beams or spare breakaway brackets / springs on hand for faster maintenance.